Rooms, readings and psychrometrics
Room Analysis is where most of a damp & mould survey’s evidence is captured: one card per room, each carrying its own readings, checklist, and photos.
What it is
Adding a room opens a card for Relative humidity (%), Temperature, and Surface temperature, plus a Water Activity (aw) value, from which the app calculates Dew Point, Vapour Pressure, Absolute Humidity and Mixing Ratio — the standard set of psychrometric values used to judge condensation risk, calculated on-device with no server round-trip. Water activity above roughly 0.70 is the threshold generally understood to support mould growth. A ventilation-adequacy check, plus optional detail on room volume, extraction type and rate, and background/purge ventilation, sits alongside the readings. A defect checklist (cracked walls, poor drainage, leaking pipes, insufficient insulation, cold bridging, and more) and a photo section, using the same photo pipeline as everywhere else, complete each room.
The Environmental Sensitivity Matrix (mould risk matrix) is a separate, explicitly-labelled simulation: it projects surface relative humidity across a range of temperature shifts while holding the room’s current moisture level constant, colour-banding each projected value from green through to red/severe. It’s a way of visualising how sensitive a room is to a temperature drop, not a second measurement.
How to do it
- Add a room and name it.
- Enter your readings — relative humidity, temperature, surface temperature, and water activity if you’re taking it.
- Review the calculated psychrometric values that appear alongside your readings.
- Tick any relevant items on the defect checklist, and complete the ventilation-adequacy check and, where enabled, the extended ventilation detail.
- Add photos for any hazard finding — required if your organisation’s photo policy applies.
- Review the mould risk matrix if you want to see how sensitive the room’s projected surface RH is to a temperature change.
- Repeat for each room in scope, including any your organisation has marked as required.
How it integrates
Room readings feed directly into the survey’s overall condensation analysis and, for damp & mould, the HHSRS scoring — see Condensation and U-value analysis. The defect checklist is shared between room and external findings, so the same vocabulary applies whichever you’re recording against. Photos attached to a room finding follow your organisation’s photo policy exactly as described in Photos, geotagging and the photo policy.
Common problems
- I don’t see the extended ventilation fields. They’re an org-level setting (on by default) — ask an admin if you expected them and they’re missing.
- The mould risk matrix shows a severe band and I’m not sure what that means. It’s a projection, not a live reading — a red/severe band means the room’s current moisture level would put surface humidity into mould-favourable territory if the temperature dropped by that much, useful context alongside your actual readings, not a replacement for them.
- A required room is missing from my list. Required rooms are set by the office when the job was raised — check the job’s briefing shown when you first opened it, or ask the office to confirm.